EN ISO 13850, “Safety of machinery – Emergency stop function – Principles for design (ISO 13850:2015)”, sets out how the emergency stop function of a machine is designed. An emergency stop lets a single human action stop the machine when a hazard arises or is about to arise. The standard covers the behaviour of the function, its devices and its reset, whatever form of energy is used.

Let us take care of EN ISO 13850 testing and the CE marking of your machine together; CE Danışmanı (CE Consultant) manages the whole process.

EN ISO 13850 harmonised standard

EN ISO 13850 at a glance

Edition cited in the EU Official JournalEN ISO 13850:2015
Official titleSafety of machinery – Emergency stop function – Principles for design (ISO 13850:2015)
Legislation supportedMachinery Directive 2006/42/EC; from 20 January 2027 Machinery Regulation (EU) 2023/1230
Type of standardType B standard
Minimum safety levelAt least PL c or SIL 1 for the emergency stop function; the actual level is set by the risk assessment

Which machines are covered?

The standard applies to all machines that have an emergency stop function. The machinery legislation requires an emergency stop device on every machine, with a few exceptions. Typical examples:

  • Presses, CNC machine tools and machining centres
  • Packaging, filling and food processing lines
  • Conveyors and long transport lines (pull-wire emergency stop)
  • Robot cells and automation lines
  • Woodworking and plastics machines

Machines where an emergency stop would not reduce the risk, and hand-held or hand-guided machines, are outside the scope. An emergency stop is a complementary protective measure; it does not replace guards or other safety functions. Emergency switching off of the electrical supply is a separate subject, dealt with in EN 60204-1.

Main requirements of the standard

  • Availability: The function is operational in all operating modes and overrides all other functions.
  • Stop category: Stop category 0 or 1 is chosen from the risk assessment; the aim is to stop the hazardous movement as quickly as possible without creating new hazards.
  • Latching: Once actuated, the device stays engaged until it is deliberately reset by hand.
  • Reset: Resetting the device does not restart the machine; it only permits a restart.
  • Device types: Mushroom-type pushbuttons, wires, ropes, bars, handles and foot pedals without a protective cover may be used.
  • Colour: The actuator is red and the background, where there is one, is yellow.
  • Location: Devices are placed at each operator station and at other places where an emergency stop may be needed, within easy reach.

EN ISO 13850 verification and checks

The emergency stop function is verified on the machine by visual inspection and functional tests. The electrical checks are done together with the EN 60204-1 tests.

Test or checkWhat is verified?
Inspection of location and accessibilityA device is present and within easy reach at each operator station
Functional testEach device stops the hazardous movement in all operating modes
Latching and reset testThe device stays engaged and resetting does not start the machine
Pull-wire testA stop signal is generated when the wire is pulled, breaks or goes slack
Safety levelThe function meets the required PL or SIL

Results are entered in the test report. Electrical emergency stop buttons are expected to have direct opening contacts; this is shown by the component standard EN 60947-5-5.

Its place in the CE marking process

  1. Risk assessment: The situations that need an emergency stop and the safety level of the function are defined under EN ISO 12100.
  2. Design: Device type, location, stop category and span of control are set to EN ISO 13850.
  3. Verification: Functional tests are carried out on the machine and the safety level is shown by calculation.
  4. Technical file: The layout, circuit diagrams, PL calculation and test records go into the technical file.
  5. Declaration of conformity: EN ISO 13850 is listed among the standards applied.

Conformity with a harmonised standard gives presumption of conformity with the relevant essential requirements of the machinery legislation. Turkey applies the same rules through its own regulation aligned with 2006/42/EC. See also CE marking of machinery.

Standards applied together

Frequently asked questions

Does an emergency stop button replace a guard?

No. An emergency stop is a complementary measure and depends on a person noticing the hazard and reacting. Access to the danger zone must be prevented separately by guards and protective devices.

Can the reset restart the machine?

No. After the device is reset, the machine may start only on a separate start command.

Which edition applies?

The edition cited in the EU Official Journal is EN ISO 13850:2015. Check the current citation before testing starts.

Other standards in this group

All standard guides

Get an offer for your product

Scope, timeline and price in three steps.

  1. 1Tell us about your productAttach a datasheet or photos if you have them
  2. 2Scope and tests become clearDirectives, tests, notified body
  3. 3Price and timeline in your handsOffer within one business day

Prefer to talk now?

Leave your details

Reply within one business day

By sending this form you agree that your data is processed as described in our Privacy & Cookie Policy.