EN ISO 14118, “Safety of machinery – Prevention of unexpected start-up (ISO 14118:2017)”, defines the design measures that prevent a machine from starting by itself or by mistake while a person is working in the hazard zone. Many accidents during maintenance, cleaning, setting and fault finding are caused by such start-ups. It replaced the earlier EN 1037.

Let us take care of EN ISO 14118 testing and the CE marking of your machine together; CE Danışmanı (CE Consultant) manages the whole process.

EN ISO 14118 harmonised standard

EN ISO 14118 at a glance

Edition cited in the EU Official JournalEN ISO 14118:2018
Official titleSafety of machinery – Prevention of unexpected start-up (ISO 14118:2017)
Legislation supportedMachinery Directive 2006/42/EC; from 20 January 2027 Machinery Regulation (EU) 2023/1230
Type of standardType B standard

Which situations are covered?

The standard covers all forms of energy: electrical supply, hydraulic and pneumatic pressure, energy stored in springs and pressure vessels, gravity and external influences. Typical causes of unexpected start-up are:

  • A start command generated by a fault in the control system or by an external influence
  • Another person starting the machine without knowing that someone is inside
  • Unintended contact with a sensor or control device
  • Return of the energy supply after an interruption
  • Release of energy left in springs, accumulators or pressurised lines
  • Suspended loads or vertical axes falling under gravity

The standard does not replace the lockout procedures of the user; it makes sure the machine is equipped so that they can be applied. Details of electrical isolation are given in EN 60204-1.

Main requirements of the standard

  • Isolation: The machine has devices that reliably isolate it from each energy source.
  • Locking in the isolated position: The isolating device can be locked off with a padlock or similar means.
  • Dissipation or restraint of stored energy: Pressure, spring force and residual voltage are dissipated; where that is not possible, the energy is restrained mechanically.
  • Verification: It must be possible to check that isolation and dissipation have taken place, for example by a pressure gauge or a visible break.
  • Location and marking: Isolating devices are easy to reach and it is clear which machine or section they isolate.
  • Measures other than isolation: Where isolation is not appropriate, control measures prevent unintended start commands from taking effect.
  • Return of energy: After an interruption the machine must not restart by itself.

EN ISO 14118 verification and checks

Verification is by visual inspection and functional tests on the machine, separately for each energy source.

Test or checkWhat is verified?
Inspection of isolating devicesA device is present, accessible and marked for each energy source
Locking checkDevices can be locked in the isolated position
Stored energy testAfter isolation the pressure is released, residual voltage falls and suspended loads are held
Loss and return of energyThe machine does not restart by itself when energy returns
Start command testA start command has no effect with a guard open or with the machine isolated

For hydraulic and pneumatic systems, the dissipation checks are assessed together with EN ISO 4413 and EN ISO 4414.

Its place in the CE marking process

  1. Risk assessment: The work done in the hazard zone (maintenance, setting, cleaning) and the unexpected movement each energy source could cause are identified under EN ISO 12100.
  2. Design: Isolating devices, dissipation means and control measures are set to EN ISO 14118.
  3. Verification: Isolation, locking and dissipation are tried out on the machine.
  4. Technical file: The list of energy sources, the diagrams and the inspection records go into the technical file.
  5. Declaration of conformity: EN ISO 14118 is listed among the standards applied.

Conformity with a harmonised standard gives presumption of conformity with the relevant essential requirements of the machinery legislation. Turkey applies the same rules through its own regulation aligned with 2006/42/EC. See also CE marking of machinery.

Standards applied together

  • EN 60204-1: Supply disconnecting device and electrical measures against unexpected start-up
  • EN ISO 4413: Isolation and dissipation of energy in hydraulic systems
  • EN ISO 4414: Isolation and dissipation of energy in pneumatic systems
  • EN ISO 13849-1: Safety functions provided by control measures

Frequently asked questions

Is pressing the emergency stop enough for maintenance?

No. An emergency stop does not isolate energy and cannot be locked. For maintenance the machine is isolated from its energy sources, the isolating device is locked and remaining energy is dissipated.

Is locking the main switch enough?

Only for electrical energy. A hydraulic accumulator, a compressed air line or a suspended axis can cause movement with the switch off; each energy source is treated separately.

Which edition applies?

The edition cited in the EU Official Journal is EN ISO 14118:2018. Check the current citation before testing starts.

Other standards in this group

All standard guides

Get an offer for your product

Scope, timeline and price in three steps.

  1. 1Tell us about your productAttach a datasheet or photos if you have them
  2. 2Scope and tests become clearDirectives, tests, notified body
  3. 3Price and timeline in your handsOffer within one business day

Prefer to talk now?

Leave your details

Reply within one business day

By sending this form you agree that your data is processed as described in our Privacy & Cookie Policy.