EN 60335-2-24, “Household and similar electrical appliances – Safety – Part 2-24: Particular requirements for refrigerating appliances, ice-cream appliances and ice makers”, sets the safety requirements for refrigerators and similar appliances. It is read together with EN IEC 60335-1; Part 2-24 holds the rules that are added or changed for these appliances. The refrigerating circuit, the compressor and above all the use of flammable refrigerants are what set it apart.
Let us take care of EN 60335-2-24 testing and the CE marking of your product together; CE Danışmanı (CE Consultant) manages the whole process.

EN 60335-2-24 at a glance
| Edition cited in the EU Official Journal | EN 60335-2-24:2010 |
|---|---|
| Official title | Household and similar electrical appliances – Safety – Part 2-24: Particular requirements for refrigerating appliances, ice-cream appliances and ice makers |
| Legislation supported | Low Voltage Directive 2014/35/EU |
| Type of standard | Product standard |
| Flammable refrigerant | Not more than 150 g in each refrigerating circuit |
Products covered
The standard applies to refrigerating appliances for household and similar use. Typical examples:
- Refrigerators and fridge-freezers
- Upright and chest freezers
- Wine coolers and minibars
- Ice-cream appliances and ice makers with a motor-compressor
- Coolers for camping, caravans and boats, compression or absorption type
Commercial refrigerating appliances such as display cabinets belong to EN 60335-2-89, and air conditioners and heat pumps to EN 60335-2-40. The motor-compressor itself is also assessed with EN 60335-2-34.
Particular requirements for refrigerating appliances
- Flammable refrigerant: Where a flammable refrigerant such as isobutane is used, the charge is limited to 150 g per circuit and the appliance carries the flammability warning sign.
- No ignition after a leak: Electrical components in areas where leaked gas can collect must not act as an ignition source; this is verified by leak simulation tests.
- Strength of the refrigerating circuit: Pipes and joints must withstand the pressure in operation and at standstill, and accessible pipes are protected against mechanical damage.
- Compressor and fan motors: With a locked rotor or a stalled fan the motor protector must operate and no overheating may occur.
- Spillage and condensation: Liquid spilled on the top or inside and defrost water must not affect the insulation.
- Child entrapment and stability: The door or lid can be opened from the inside, and the appliance must not overturn with doors open and shelves loaded.
- Marking and instructions: Refrigerant type and charge, the insulation blowing gas and the climate class are marked; the instructions warn, among other things, against blocking the ventilation openings.
Typical test programme
EN 60335-1 and EN 60335-2-24 are applied together. Heating tests run at the ambient temperature that corresponds to the declared climate class.
| Test or check | What is verified? |
|---|---|
| Power input and current | The declared values are within the permitted deviation |
| Heating test | Temperatures of the compressor winding, cords and surfaces stay within limits |
| Spillage test and leakage current | Electric strength is kept after liquid has been spilled |
| Abnormal operation | No hazard with locked rotor, stalled fan or failed thermostat |
| Leak simulation (flammable refrigerants) | Leaked gas does not reach a dangerous concentration around electrical components, or the components are of a suitable type |
| Pressure test of the circuit | The circuit withstands the pressure without leaking |
| Stability and door test | The appliance does not overturn and the door opens from the inside |
Place in the CE marking process
- Risk assessment: Hazards of electric shock, fire, explosion and mechanical injury are identified for the refrigerant used.
- Design: The refrigerant charge and the position and type of electrical components are chosen to meet the standard.
- Verification and testing: The sample is tested to EN 60335-1 and EN 60335-2-24; EMC tests and energy label measurements are done separately.
- Technical file: Test reports, diagrams, the list of critical components and the instructions go into the technical file.
- Declaration of conformity: EN 60335-2-24 is listed among the standards applied and the CE marking is affixed.
Compliance with the harmonised standard gives presumption of conformity with the relevant essential requirements of the Low Voltage Directive. Turkey applies the same rules through its own aligned regulation.
Standards applied together
- EN 60335-2-34: motor-compressors
- EN 55014-1 and EN 55014-2: EMC emission and immunity of household appliances
- RoHS: restriction of hazardous substances
- Energy labelling and ecodesign rules: energy class and efficiency of refrigerating appliances are assessed separately
Frequently asked questions
Is EN 60335-2-24 enough on its own?
No. Part 2-24 is applied together with EN 60335-1 and the test report covers both. EMC, RoHS, energy labelling and ecodesign are assessed separately.
Does a refrigerator with a flammable refrigerant need extra tests?
Yes. Compliance with the charge limit, leak simulation and marking are verified in addition, and the position of the electrical components directly affects the result.
Which edition applies?
The edition cited in the EU Official Journal is EN 60335-2-24:2010. Check the current citation before testing starts.
Other standards in this group
- EN 60335-2-15: Appliances for Heating Liquids
- EN 60335-2-21: Storage Water Heaters
- EN 60335-2-30: Room Heaters
- EN 60335-2-40: Heat Pumps and Air Conditioners
