EN 60335-2-40, “Household and similar electrical appliances – Safety – Part 2-40: Particular requirements for electrical heat pumps, air-conditioners and dehumidifiers”, sets the safety requirements for air-conditioning appliances with a motor-compressor. It is read together with EN IEC 60335-1; Part 2-40 holds the rules that are added or changed for these appliances. The refrigerating circuit under pressure and the use of flammable refrigerants are what set it apart.

Let us take care of EN 60335-2-40 testing and the CE marking of your product together; CE Danışmanı (CE Consultant) manages the whole process.

EN 60335-2-40 harmonised standard

EN 60335-2-40 at a glance

Edition cited in the EU Official JournalEN 60335-2-40:2003
Official titleHousehold and similar electrical appliances – Safety – Part 2-40: Particular requirements for electrical heat pumps, air-conditioners and dehumidifiers
Legislation supportedLow Voltage Directive 2014/35/EU
Type of standardProduct standard

Products covered

The standard applies to electrical heat pumps, air conditioners and dehumidifiers that contain a motor-compressor. Typical examples:

  • Split and multi-split air conditioners with indoor and outdoor units
  • Portable and window air conditioners
  • Air-to-water and air-to-air heat pumps
  • Sanitary hot water heat pumps
  • Dehumidifiers and fan coil units

Household refrigerators belong to EN 60335-2-24 and commercial refrigerating appliances to EN 60335-2-89. The motor-compressor itself is also assessed with EN 60335-2-34.

Particular requirements for heat pumps and air conditioners

  • Pressure strength of the circuit: Pipes, heat exchangers and joints must withstand the pressure that can occur in operation and under fault conditions; a pressure-limiting device is fitted where needed.
  • Flammable refrigerant: The permitted charge depends on the flammability of the refrigerant, the floor area of the room and the installation height; the appliance carries the flammability warning sign.
  • No ignition after a leak: Electrical components in areas where leaked gas can collect must not act as an ignition source.
  • Compressor and fan motors: Protective devices must operate with a locked rotor, a stalled fan or loss of air or water flow.
  • Supplementary electric heaters: Where heaters are fitted, a thermal cut-out must open the circuit when the air flow is restricted.
  • Protection against water: Outdoor units must withstand rain, and overflowing condensate must not reach live parts.
  • Installation and service instructions: The manual covers minimum room area, pipework, refrigerant charging and service by competent persons; refrigerant type and charge, permitted pressures and electrical ratings are on the rating plate.

Typical test programme

EN 60335-1 and EN 60335-2-40 are applied together. Heating tests run in a climatic chamber under the most severe operating conditions intended for the appliance.

Test or checkWhat is verified?
Power input and currentThe declared values are within the permitted deviation
Heating testTemperatures of the compressor winding, cords and components stay within limits
Leakage current and electric strengthInsulation is adequate at operating temperature and after the humidity test
Rain and condensate overflow testWater does not reach live parts
Abnormal operationNo hazard with locked rotor, stalled fan or loss of air or water flow
Pressure testsThe refrigerating circuit withstands the pressure without leaking
Leak simulation (flammable refrigerants)Leaked gas does not reach an ignition source

Place in the CE marking process

  1. Risk assessment: Hazards of electric shock, fire, explosion and pressure are identified for the refrigerant used and the way the appliance is installed.
  2. Design: The refrigerant charge, pressure limiters and type of electrical components are chosen to meet the standard.
  3. Verification and testing: The sample is tested to EN 60335-1 and EN 60335-2-40; EMC tests and efficiency measurements are done separately.
  4. Technical file: Test reports, diagrams, the list of critical components and the instructions go into the technical file.
  5. Declaration of conformity: EN 60335-2-40 is listed among the standards applied and the CE marking is affixed.

Compliance with the harmonised standard gives presumption of conformity with the relevant essential requirements of the Low Voltage Directive. Turkey applies the same rules through its own aligned regulation.

Standards applied together

  • EN 60335-2-34: motor-compressors
  • EN 378 series: safety and environmental requirements for refrigerating systems and heat pumps
  • EN 55014-1 and EN 55014-2: EMC emission and immunity of household appliances
  • RoHS: restriction of hazardous substances
  • Ecodesign and energy labelling rules, plus fluorinated gas and pressure equipment rules depending on the refrigerant and the size of the circuit

Frequently asked questions

Is EN 60335-2-40 enough on its own?

No. Part 2-40 is applied together with EN 60335-1 and the test report covers both. EMC, RoHS, ecodesign and energy labelling are assessed separately.

What matters for an air conditioner with a flammable refrigerant?

The charge is assessed together with the size of the room where the unit will be installed. The minimum room area is stated in the manual, and it is verified that electrical components are not an ignition source.

Which edition applies?

The edition cited in the EU Official Journal is EN 60335-2-40:2003. A newer CENELEC edition has been published; for presumption of conformity the edition cited in the Official Journal is the reference. Check the current citation before testing starts.

Other standards in this group

All standard guides

Get an offer for your product

Scope, timeline and price in three steps.

  1. 1Tell us about your productAttach a datasheet or photos if you have them
  2. 2Scope and tests become clearDirectives, tests, notified body
  3. 3Price and timeline in your handsOffer within one business day

Prefer to talk now?

Leave your details

Reply within one business day

By sending this form you agree that your data is processed as described in our Privacy & Cookie Policy.