EN 60335-2-40, “Household and similar electrical appliances – Safety – Part 2-40: Particular requirements for electrical heat pumps, air-conditioners and dehumidifiers”, sets the safety requirements for air-conditioning appliances with a motor-compressor. It is read together with EN IEC 60335-1; Part 2-40 holds the rules that are added or changed for these appliances. The refrigerating circuit under pressure and the use of flammable refrigerants are what set it apart.
Let us take care of EN 60335-2-40 testing and the CE marking of your product together; CE Danışmanı (CE Consultant) manages the whole process.

EN 60335-2-40 at a glance
| Edition cited in the EU Official Journal | EN 60335-2-40:2003 |
|---|---|
| Official title | Household and similar electrical appliances – Safety – Part 2-40: Particular requirements for electrical heat pumps, air-conditioners and dehumidifiers |
| Legislation supported | Low Voltage Directive 2014/35/EU |
| Type of standard | Product standard |
Products covered
The standard applies to electrical heat pumps, air conditioners and dehumidifiers that contain a motor-compressor. Typical examples:
- Split and multi-split air conditioners with indoor and outdoor units
- Portable and window air conditioners
- Air-to-water and air-to-air heat pumps
- Sanitary hot water heat pumps
- Dehumidifiers and fan coil units
Household refrigerators belong to EN 60335-2-24 and commercial refrigerating appliances to EN 60335-2-89. The motor-compressor itself is also assessed with EN 60335-2-34.
Particular requirements for heat pumps and air conditioners
- Pressure strength of the circuit: Pipes, heat exchangers and joints must withstand the pressure that can occur in operation and under fault conditions; a pressure-limiting device is fitted where needed.
- Flammable refrigerant: The permitted charge depends on the flammability of the refrigerant, the floor area of the room and the installation height; the appliance carries the flammability warning sign.
- No ignition after a leak: Electrical components in areas where leaked gas can collect must not act as an ignition source.
- Compressor and fan motors: Protective devices must operate with a locked rotor, a stalled fan or loss of air or water flow.
- Supplementary electric heaters: Where heaters are fitted, a thermal cut-out must open the circuit when the air flow is restricted.
- Protection against water: Outdoor units must withstand rain, and overflowing condensate must not reach live parts.
- Installation and service instructions: The manual covers minimum room area, pipework, refrigerant charging and service by competent persons; refrigerant type and charge, permitted pressures and electrical ratings are on the rating plate.
Typical test programme
EN 60335-1 and EN 60335-2-40 are applied together. Heating tests run in a climatic chamber under the most severe operating conditions intended for the appliance.
| Test or check | What is verified? |
|---|---|
| Power input and current | The declared values are within the permitted deviation |
| Heating test | Temperatures of the compressor winding, cords and components stay within limits |
| Leakage current and electric strength | Insulation is adequate at operating temperature and after the humidity test |
| Rain and condensate overflow test | Water does not reach live parts |
| Abnormal operation | No hazard with locked rotor, stalled fan or loss of air or water flow |
| Pressure tests | The refrigerating circuit withstands the pressure without leaking |
| Leak simulation (flammable refrigerants) | Leaked gas does not reach an ignition source |
Place in the CE marking process
- Risk assessment: Hazards of electric shock, fire, explosion and pressure are identified for the refrigerant used and the way the appliance is installed.
- Design: The refrigerant charge, pressure limiters and type of electrical components are chosen to meet the standard.
- Verification and testing: The sample is tested to EN 60335-1 and EN 60335-2-40; EMC tests and efficiency measurements are done separately.
- Technical file: Test reports, diagrams, the list of critical components and the instructions go into the technical file.
- Declaration of conformity: EN 60335-2-40 is listed among the standards applied and the CE marking is affixed.
Compliance with the harmonised standard gives presumption of conformity with the relevant essential requirements of the Low Voltage Directive. Turkey applies the same rules through its own aligned regulation.
Standards applied together
- EN 60335-2-34: motor-compressors
- EN 378 series: safety and environmental requirements for refrigerating systems and heat pumps
- EN 55014-1 and EN 55014-2: EMC emission and immunity of household appliances
- RoHS: restriction of hazardous substances
- Ecodesign and energy labelling rules, plus fluorinated gas and pressure equipment rules depending on the refrigerant and the size of the circuit
Frequently asked questions
Is EN 60335-2-40 enough on its own?
No. Part 2-40 is applied together with EN 60335-1 and the test report covers both. EMC, RoHS, ecodesign and energy labelling are assessed separately.
What matters for an air conditioner with a flammable refrigerant?
The charge is assessed together with the size of the room where the unit will be installed. The minimum room area is stated in the manual, and it is verified that electrical components are not an ignition source.
Which edition applies?
The edition cited in the EU Official Journal is EN 60335-2-40:2003. A newer CENELEC edition has been published; for presumption of conformity the edition cited in the Official Journal is the reference. Check the current citation before testing starts.
Other standards in this group
- EN 60335-2-24: Refrigerating Appliances
- EN 60335-2-30: Room Heaters
- EN 60335-2-80: Fans
- EN 60335-2-23: Skin and Hair Care Appliances