EN 61000-3-3, “Electromagnetic compatibility (EMC) – Part 3-3: Limits – Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection”, limits how much a product may disturb the mains voltage when it switches on and off. Laboratories call it the “flicker test”; in EMC testing it is carried out together with the harmonic measurement (EN 61000-3-2).

Let us take care of EN 61000-3-3 measurements and the CE marking of your product together; CE Danışmanı (CE Consultant) manages the whole process.

EN 61000-3-3 harmonised standard

What does this test measure?

When a compressor, heater or motor starts, it draws a sudden current from the mains; because of the line impedance the voltage dips for a moment and the lamps on the same line blink. This is called flicker. Each dip is small, but when it repeats often it tires the eye and annoys people.

The flicker measurement records the voltage changes the equipment causes at its point of connection, passes them through a filter that imitates the perception of the human eye and calculates the short-term and long-term flicker severity.

EN 61000-3-3 at a glance

Current editionEN 61000-3-3:2013 and its amendments (IEC 61000-3-3:2013 + A1:2017 + A2:2021)
Official titleElectromagnetic compatibility (EMC) – Part 3-3: Limits – Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection
Type of standardMains emission standard: it gives the limits and the measurement circuit itself
LegislationEMC Directive 2014/30/EU; the generic emission standard EN 61000-6-3 refers to it

Which products does it apply to?

Equipment connected to the public low-voltage network with a rated current of up to 16 A per phase that is not subject to conditional connection. Equipment unlikely to produce significant voltage fluctuations need not be measured; this is decided from the circuit diagram and a short functional test.

  • Typical candidates: refrigerator and air-conditioner compressors, thermostatically controlled heaters, washing machines and dishwashers, copiers, welding equipment, hair dryers.
  • For manual switching, equipment is deemed to comply without measurement if the inrush current stays below 20 A in every half cycle and the current then remains within a 1.5 A band.
  • Equipment that fails with the reference impedance may be assessed under EN 61000-3-11 by way of conditional connection, up to 75 A.

Measurement setup

EN 61000-3-3 flicker measurement setup (schematic)

  1. Reference impedance: the equipment is fed through a reference impedance representing a typical domestic supply: 0.24 Ω resistance and 0.15 Ω inductive reactance in the phase branch, 0.16 Ω and 0.10 Ω in the neutral branch. The values come from IEC TR 60725.
  2. Supply source: the source’s own internal impedance counts as part of these values; the source voltage is held constant during the measurement.
  3. Flickermeter: an instrument to IEC 61000-4-15 monitors the voltage at the point of connection and delivers Pst, Plt, dc, dmax and Tmax.
  4. Operating condition: the equipment runs through the cycle that produces the largest voltage change; for products such as cooking hobs and copiers the standard defines specific conditions.
  5. Observation period: 10 minutes for the short-term severity Pst, 2 hours for the long-term severity Plt; Plt is calculated from 12 consecutive Pst values.

Limits

QuantityMeaningLimit
PstShort-term flicker severity (10 min)≤ 1.0
PltLong-term flicker severity (2 h)≤ 0.65
dcRelative steady-state voltage change≤ 3.3 %
dmaxMaximum relative voltage change4 %; 6 % for manually switched equipment; 7 % for attended equipment or equipment switched on at most twice a day
TmaxTotal time d(t) exceeds 3.3 % in a single change≤ 500 ms

The 6 % and 7 % options apply only to equipment with a delayed or manual restart after a supply interruption; equipment that restarts automatically at once is held to 4 %.

How is compliance assessed?

  • All five quantities must stay within their limits; the result is a single pass or fail decision.
  • The Pst and Plt limits are not applied to changes caused by manual switching; changes caused by emergency switching are not assessed at all.
  • Instead of a measurement, a calculation method may be used where the voltage change characteristic is known.

Place in the CE marking process

  1. The rated current and the switching behaviour of the equipment are determined; it is decided whether a measurement is needed.
  2. Soft starting, inrush limiting and zero-crossing switching are reviewed during design; a pre-measurement is made if needed.
  3. The measurement is carried out in an accredited laboratory; the report records the operating cycle, the dmax option applied and the measured values.
  4. The report goes into the technical file; the EU Declaration of Conformity under the EMC Directive is drawn up and the product is CE marked.

Standards applied together

  • EN 61000-3-2: harmonic current emission limits
  • EN 61000-3-11: flicker for equipment up to 75 A subject to conditional connection
  • EN 61000-6-3 and EN 61000-6-4: generic emission for residential and industrial environments
  • EN 55014-1: high-frequency emission of household appliances

Frequently asked questions

What is the difference between Pst and Plt?

Pst is the flicker severity perceived over a 10 minute window; a value of 1.0 corresponds to the threshold at which half of the observers start to feel annoyed. Plt is calculated over a 2 hour window from 12 consecutive Pst values and measures long-term annoyance; its limit is lower, 0.65.

What if my product draws more than 16 A?

This standard covers equipment up to 16 A. Equipment above 16 A up to 75 A, and equipment that fails with the reference impedance, falls under EN 61000-3-11; there the manufacturer declares the maximum permissible system impedance or marks the equipment for premises with a service capacity of 100 A or more only.

What if my product exceeds the limits?

The inrush current is usually limited: a soft starter for motors, zero-crossing switching for heaters, staged starting for compressors. The thermostat cycling rate of heaters is also adjusted to reduce the number of voltage changes. The measurement is then repeated with the same cycle.

Other standards in this group

All standard guides

Our EMC test requirements tool shows which EMC tests your product needs in a few questions.

Get an offer for your product

Scope, timeline and price in three steps.

  1. 1Tell us about your productAttach a datasheet or photos if you have them
  2. 2Scope and tests become clearDirectives, tests, notified body
  3. 3Price and timeline in your handsOffer within one business day

Prefer to talk now?

Leave your details

Reply within one business day

By sending this form you agree that your data is processed as described in our Privacy & Cookie Policy.