EN 55011, “Industrial, scientific and medical equipment – Radio-frequency disturbance characteristics – Limits and methods of measurement”, limits the radio-frequency disturbance that industrial, scientific and medical (ISM) equipment sends into its surroundings. It is an emission standard and does not cover immunity. It is widely used on the emission side of EMC testing for industrial products.

Let us take care of EN 55011 testing and the CE marking of your product together; CE Danışmanı (CE Consultant) manages the whole process.

EN 55011 harmonised standard

EN 55011 at a glance

Edition cited in the EU Official JournalEN 55011:2016
Official titleIndustrial, scientific and medical equipment – Radio-frequency disturbance characteristics – Limits and methods of measurement
Legislation supportedEMC Directive 2014/30/EU
Type of standardEMC product family standard

Products covered

The standard applies to equipment used for industrial, scientific and medical purposes, and to domestic appliances that use radio-frequency energy to treat material. Typical examples:

  • Industrial power converters, chargers and power supplies
  • Laboratory, measurement and control equipment
  • Medical electrical equipment
  • Induction heating and high-frequency welding equipment

Many product standards refer to EN 55011 for emission: EN 60601-1-2 for medical devices, EN 61326-1 for laboratory equipment and EN IEC 60974-10 for arc welding equipment. Household appliances fall under EN 55014-1 and multimedia equipment under EN 55032.

Main requirements of the standard

  • Group 1: All equipment that is not Group 2; radio-frequency energy is generated only for the internal working of the equipment.
  • Group 2: Equipment that intentionally generates and uses radio-frequency energy to treat or inspect material or to transfer energy.
  • Class A: Equipment suitable for use in locations other than residential ones and those directly connected to a low-voltage network supplying dwellings.
  • Class B: Equipment suitable for residential locations and those directly connected to a low-voltage network supplying dwellings; its limits are stricter.
  • Conducted disturbance: Disturbance voltage at the mains port is measured from 150 kHz to 30 MHz.
  • Radiated disturbance: Field strength is measured from 30 MHz to 1 GHz; for Group 2, magnetic field below 30 MHz and, for equipment working at high frequency, measurements above 1 GHz are added.

EN 55011 tests

Measurements are made on a test site; for Class A equipment that cannot be moved because of size or power, measurement in situ is also possible.

Test or checkWhat is verified?
Disturbance voltage at the mains portDisturbance conducted into the mains is below the limits for the group and class
Radiated electric fieldField strength radiated by the equipment and its cables is below the limits
Magnetic field measurement (Group 2)The magnetic field component below 30 MHz is below the limits
Measurement above 1 GHz (Group 2)Radiation from equipment working at microwave frequencies is below the limits
In situ measurementClass A equipment measured where it is installed meets the limits

Its place in CE marking

  1. EMC assessment: The environment, the ports and the applicable emission and immunity standards are identified.
  2. Design: Filtering, shielding and cable layout are designed with the limits of the group and class in mind.
  3. Testing: Emission is measured to EN 55011; immunity is tested to the relevant product standard or generic standard.
  4. Technical file: The test report, set-up photographs and diagrams go into the technical file.
  5. Declaration of conformity: EN 55011 is listed among the standards applied and the CE marking is affixed.

Conformity with a harmonised standard gives presumption of conformity with the corresponding essential requirements of the EMC Directive 2014/30/EU.

Standards applied together

  • EN IEC 61000-6-2: Generic immunity standard for industrial environments
  • EN IEC 61000-6-4: Generic emission standard for industrial environments
  • EN 60601-1-2: Electromagnetic disturbances for medical electrical equipment
  • EN 61326-1: EMC requirements for measurement, control and laboratory equipment
  • EN 62477-1: Safety of power electronic converters
  • EN 55014-1 and EN 55032: Emission of household appliances and multimedia equipment

Frequently asked questions

Is my equipment Group 1 or Group 2?

If radio-frequency energy does the main job of the product, such as heating, welding or treating material, it is Group 2. If the energy is generated only for the internal circuits, it is Group 1; most industrial equipment is in this group.

Can Class A equipment be used in a home?

Class A equipment is not designed for residential use and may disturb radio reception there. This is stated in its documents; a product for residential use must meet the Class B limits.

Which edition applies?

The edition cited in the EU Official Journal under the EMC Directive is EN 55011:2016. Check the current citation before testing starts.

Other standards in this group

  • EN 55032: EMC Emission of Multimedia Equipment
  • EN 55035: EMC Immunity of Multimedia Equipment
  • EN 55015: Radio Disturbance of Lighting Equipment
  • EN 55014-1: EMC Emission of Household Appliances

All standard guides

Our EMC test requirements tool shows which EMC tests your product needs in a few questions.

Get an offer for your product

Scope, timeline and price in three steps.

  1. 1Tell us about your productAttach a datasheet or photos if you have them
  2. 2Scope and tests become clearDirectives, tests, notified body
  3. 3Price and timeline in your handsOffer within one business day

Prefer to talk now?

Leave your details

Reply within one business day

By sending this form you agree that your data is processed as described in our Privacy & Cookie Policy.